SRP-E300/302
Ver. 1.01 BIXOLON
- 114 -
For range ②
m
Bar Code System
Range of k
Range of d
65
UPC-A
11 ≤ n ≤ 12
48 ≤ d ≤ 57
66
UPC-E
11 ≤ n ≤ 12
48 ≤ d ≤ 57
67
JAN13(EAN)
12 ≤ n ≤ 13
48 ≤ d ≤ 57
68
JAN8(EAN)
7 ≤ n ≤ 8
48 ≤ d ≤ 57
69
CODE39
1 ≤ n ≤ 255
48 ≤ d ≤ 57, 65 ≤ d ≤ 90,
d=32,36,37,43,45,46,47
70
ITF
1 ≤ n ≤ 255 (even number)
48 ≤ d ≤ 57
71
CODABAR
1 ≤ n ≤ 255
48 ≤ d ≤ 57, 65 ≤ d ≤ 68,
d=36,43,45,46,47,58
72
CODE93
1 ≤ n ≤ 255
0 ≤ d ≤ 127
73
CODE128
2 ≤ n ≤ 255
0 ≤ d ≤ 127
74
GS1-128
2 ≤ n ≤ 255
0 ≤ d ≤ 127
75
GS1 DataBar Omnidirection
n = 13
48 ≤ d ≤ 57
76
GS1 DataBar Truncated
n = 13
48 ≤ d ≤ 57
77
GS1 DataBar Limited
n = 13
48 ≤ d ≤ 57
Remarks:
■ The bar code width exceeding the print area can not be specified.
■ Except for character size and upside-down printing mode, none of print mode such as emphasized, double-strike, etc,
affects the printing of the barcode.
■ The quiet zone of the bar code (left and right spaces of the bar code) should be considered when using this
command.
Differences:
None