<Function 64> GS ( L pL pH m fn d1 d2 (fn=64)
Code:
ASCII
GS
(
L
pL
pH
m
fn
d1
d2
Hex
1D
28
4C
pL
pH
m
fn
d1
d2
Decimal
29
40
76
pL
pH
m
fn
d1
d2
Range:
(pL + pH x 256) = 4 (pL=4, pH=0)
m=48
fn=64
d1=75, d2=67
Default:
None
Description:
Transmits the defined NV graphics key code list.
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
72H
114
1 byte
Status
40H or 41H
64 or 65
1 byte
Data
30H 39H
48 - 57
2 - 80 bytes
NUL
00H
0
1 byte
When the key code is not present :
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
72H
114
1 byte
Status
40H
64
1 byte
NUL
00H
0
1 byte