2,092 8,50 17,78
K
0,000 8,50 0,00
K
Operating instruction EC II Operation
6 − 5
6.107.98.5.01.44
6.6 Constant (fixed)
A fixed constant can, for example, be used for several consecutive sales of the same product.
_______________________________________________________________________
Fixing a constant is dependent on the Pr 514 menu setting.
_______________________________________________________________________
Constant fixing of:
Unit price
or
Tare value
or
Unit price and tare value
Switch on fixing function
Press the <Fix> key.
The ”
” or ” ” icon lights up (depending on country).
After removing the load from the scales the current value remains fixed.
Switch off fixing function
Press the <Fix> key again.
The ”
” or ” ” icon light goes off (depending on country).
After removing the load from the scales the display shows a zero.
Example: Pr 514 menu setting = 0.
Press the <Fix> key.
Place the product on the scales.
Enter the unit price, e.g. 8.50.
Read off the selling price.
Remove the product from the scales.
The unit price is not deleted.
6