20.9.2 Selecting polarity
For the package ejector or the dividers, the active signal level can be set accordingly. Ex-
ample: Package ejector. The procedure for dividers is analog. The following settings are
possible:
"+": Positive logic. A signal change from 0 V to +24 V is an active
signal. Standard setting.
"-": Negative logic. A signal change of +24 V to 0 V is an active sig-
nal.
Mode level: 5
Select polarity for package ejector.
<Automat> / <Dividers> / <Package ejector> / <Polarity pckg. eject.>
Tap the softkey until the required setting is highlighted.