EasyManua.ls Logo

BK Precision 1760A - Technical Specifications; A and B Main Supplies Specifications; Auxiliary 4-6.5 V Supply Specifications

BK Precision 1760A
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
SPECIFICATIONS
“A” AND “B” SUPPLIES
Output Voltage Range:
0V to 30V (model 1760A)
0V to 35V (model 1761)
0V to 60V (model 1762)
Output Current Limit Range:
0.1A to 2A (model 1760A and 1762)
0.1A to 3A (model 1761)
Load Regulation (Constant Voltage):
≤0.01% + 3 mV
Line Regulation 108 - 132 V (Constant Voltage):
≤0.01% + 3 mV
Ripple (Constant Voltage):
≤1 mV RMS
Recovery Time (Constant Voltage):
≤100 uS
Temp. Coefficient (Constant Voltage):
<300 ppm/°C
Load Regulation (Constant Current):
≤0.2% + 3mA
Line Regulation 108 - 132 V (Constant Current):
≤0.2% + 3mA
Ripple Current (at 108 V for Constant Current):
≤3mA RMS
Tracking (Series) Accuracy:
±0.2% + 10mV
Tracking Series, “B” tracks “A”:
5% to 100%
Panel Meter Accuracy (Volts):
±0.5% + 9 digits.*
Panel Meter Accuracy (Current):
±0.5% + 9 digits.*
(* see note 1)
“Third” SUPPLY
Output Voltage Range:
4V to 6.5V (2V to 6.5V model 1761)
Load Regulation (Constant Voltage):
≤10mV (0 to 5A load)
Line Regulation 108 - 132V (Constant Voltage):
≤10mV
Ripple and Noise:
≤2mV RMS
Over Voltage Protection Threshold:
6.8V to 7.3V
Panel Meter Accuracy:
Same as “A” Supply Meter.