101-A00 page 2/12
SAFETY DATA
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous
machinery can
cause serious
personal injury.
Hazardous voltage.
Can shock, burn or
cause death.
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous or toxic
fluids can cause
serious injury.
Hazardous pressure
can cause serious
personal injury or
property damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause serious
personal injury or property damage.
Do not operate
without guard in
place
Hazardous pressure
can cause serious
personal injury or
property damage
PUMP DATA
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA
XF1, XB1 XF1P, XB1P
Maximum Pump Speed
1,750 RPM 1,750 RPM
Maximum Temperature
240°F
(115°C)
240°F
(115°C)
Maximum Viscosity
100 SSU
(20 cP)
100 SSU
(20 cP)
Maximum Differential
Pressure
125 psi
(8.6 Bar)
125 psi
(8.6 Bar)
Maximum Working
Pressure
350 psi
(24.1 Bar)
350 psi
(24.1 Bar)
Technical Data is for standard materials of
construction. Consult Blackmer Material Specs for
optional materials of construction.
cP (centipoise) = centistokes at fluid specific gravity of 1.0
INITIAL START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Pressure Gauge Reading:
________________________
Vacuum Gauge Reading: ________________________
Flow Rate: ___
_________________________________