POOR FLOW FROM THE POND MONSTA
• Follow clearing blockages procedure page 10 Check the hose attachment, the motor housing
and the brush head inlet for blockages like large clumps of blanket weed, large stones, sticks
or any other large pond debris.
• If the impeller has been changed, check it has been correctly fitted. (see page 12)
• Ensure the outlet hose is not kinked or crushed.
• Only use smooth bore hose as hose with edges on the inside will restrict flow massively.
• Check all air is released from air outlet.
NO POWER TO THE MOTOR
• The LED is glowing red on the RF receiver but there is no action when activating the handle
lever? Check the batteries are correctly fitted in the remote control handle and the handle
hasn’t got any water inside the casing. If so place inside a warm area to let the water evaporate.
If the Monsta has been in used for prolonged periods, the battery will need replacing.
• The Led’s on the receiver are not glowing when plugged into the mains. Also check your
Plug in RCD and house fuse box RCD. Check fuse in three pin plug if so replace and test again.
• The Led’s are glowing red on the receiver and turning green when the trigger on the handle
is compressed but still no action from the motor? This may mean the motor has overheated,
the motor will reset when cooled after 15 minutes.
FAULTS - PROBLEMS PROCEDURE
Before returning your Pond Monsta to your dealer or contacting our Consumer Advice Department,
please carry out the following steps. This will solve most problems quickly and easily.
1. Ensure electrical procedure has been followed fully. Check fuse and any cable connectors/
switch boxes.
NOTE: If the pump has overheated the thermal overload will temporarily switch off the pump.
2. (a) Follow ‘Clearing Blockages’ on page 10. (b) Follow ‘Troubleshooting’ guide above.
3. Return pump to point of purchase for inspection and advice (You may need proof of purchase).
CONSUMER ADVICE CONTACT DETAILS
Interpet (Blagdon) Consumer Advice Department Vincent Lane, Dorking, Surrey RH4 3YX
Telephone: 0845 226 7437
(Monday to Friday 10am to 1pm except Bank Holidays - Times may vary)
Fax: 01306 876712 E-mail: customercare@interpet.co.uk
www.blagdonthepondmasters.co.uk
MAINTENANCE
REMOVING AND FITTING IMPELLER
Step 1. Remove impeller cover.
Step 2. Place flat-head screwdriver into centre of the impeller.
Step 3. Using your other hand, twist the impeller anti-clockwise.
Step 4. After twisting the impeller six times anti-clockwise, the impeller will be free
from the shaft.
Step 5. Select small, medium or large impeller.
Step 6. Place impeller onto shaft with the grooves facing towards you.
Step 7. Turn the impeller clockwise six times and it will be fitted correctly.
TROUBLESHOOTING
IMPORTANT
ALWAYS ENSURE THE MAINS
PLUG IS DISCONNECTED BEFORE
OPENING IMPELLER COVER.
LOCK
RELEASE
12
13
Monsta_Instructions_AW.qxd 12/5/09 12:23 Page 15