How to stop a Blanco Plumbing Product mixer tap from dripping?
- JJessica HendersonSep 13, 2025
To stop the mixer tap from dripping, re-calibrate the system.
How to stop a Blanco Plumbing Product mixer tap from dripping?
To stop the mixer tap from dripping, re-calibrate the system.
What to do if there is Error 2 (leak) in Blanco CHOICE Icona?
If you see Error 2, indicating a leak, check for water in the base cabinet. If water is present, trigger the kitchen or apartment fuse in the building’s electrical installation and disconnect the power supply. Check the system for water by viewing through the rear ventilation slits, tilting to allow any water to drain. After 15 minutes, reconnect the power supply and confirm the malfunction on the display by pressing 'OK'. Operate the system, dispensing 2 liters of each water type (hot, sparkling, and still), and wait 15 minutes. Then, inspect for any leaks in the base cabinet. If leaks persist, contact BLANCO Customer Service.
Why does my Blanco CHOICE Icona Plumbing Product show Error 9 (overheating) and the fan is noisy?
Error 9 indicates overheating, possibly accompanied by a noisy fan. First, wait 30 minutes to see if the error resolves itself automatically. If it doesn't, disconnect the power supply, wait 5 minutes, and then reconnect it. Check for nearby heat sources or heat accumulation in the base cabinet. Ensure proper ventilation by repositioning the water conditioning unit if needed, checking and improving ventilation openings in the base cabinet, and clearing any blockages from air inlets and outlets. If the issue continues, contact BLANCO Customer Service.
How to fix a weak or incorrect sparkling water spray pattern in Blanco CHOICE Icona Plumbing Product?
To resolve a weak or incorrect sparkling water spray, replace the CO cylinder. Additionally, use the enclosed spanner to open the jet aerator on the mixer tap and clean it. Finally, check the installation to ensure corner valves are fully open, the filter and CO cylinder are fully screwed in, and the supply hose isn't kinked.
Why are the dispensing quantities of refined water incorrect on my Blanco Plumbing Product?
If the dispensing quantities of the refined water types are incorrect, re-calibrate the system. Also, check the routing of the blue and red plastic tubes (cool and hot water tubes) and the flexible hoses for any kinks.
Why does the CO bottle freeze during the cleaning program of my Blanco CHOICE Icona?
If the CO bottle freezes over during the cleaning program, allow the cleaning program to continue running. Ensure the filter is correctly inserted and carry out the cleaning again with the filter inserted.
What should I do if my Blanco CHOICE Icona displays Error 14 - boiler sensor 1?
If Error 14 appears, press 'OK' on the display to confirm the malfunction. Disconnect the power supply, wait 5 minutes, and then reconnect it. If the problem continues, contact BLANCO Customer Service.
What should I do if my Blanco CHOICE Icona displays Error 15 - boiler sensor 2?
If Error 15 appears, press 'OK' on the display to confirm the malfunction. Disconnect the power supply, wait 5 minutes, and then reconnect it. If the problem continues, contact BLANCO Customer Service.
What to do if Blanco CHOICE Icona Plumbing Product shows Error 12 - no water in the boiler?
If you see Error 12, which indicates no water in the boiler, press 'OK' on the display to confirm the malfunction. Then, disconnect the power supply, wait 5 minutes, and reconnect it.
What does it mean if the LED on my Blanco CHOICE Icona mixer tap flashes red, but there's no error on the display?
If the LED on the mixer tap flashes red without an error message on the display, disconnect the power supply, wait 5 minutes, and then reconnect it. If the problem continues, contact BLANCO Customer Service.
Brand | Blanco |
---|---|
Model | CHOICE Icona |
Category | Plumbing Product |
Language | English |
Provides contact details for BLANCO Customer Service and aftersales support.
Important instructions for first-time use, including cooling time and spray pattern settling.
Covers user age, installation environment, electrical safety, and handling of components.
Highlights risks associated with CO₂ inhalation, hot water, and magnets.
Labels and identifies the mixer tap, sink, water conditioning unit, and other system parts.
Details the unit's display, flap, CO₂ cylinder, filters, and rating plate.
Identifies the tap's switch button, spray head, rotary arm, and operating levers.
Explains the adjustment wheel for water type/quantity and the touch sensor.
Explains how to operate the rotary arm and select water types like cold, hot, mixed.
Details dispensing cold water, including sparkling, medium, and still.
Explains selecting water quantity, advanced settings, and app integration.
Explains the meaning of LED ring colors and patterns for system status.
Details how to access and use menu options like temperature, connectivity, reset, clean, volume.
Explains how to adjust cold (Temp C) and hot (Temp H) water temperatures.
Outlines the benefits and functionalities of the mobile app for system control.
Step-by-step guide on how to safely replace the CO₂ cylinder.
Detailed steps for performing system cleaning and replacing the filter.
Guide to recalibrate dispensed water quantities for optimal accuracy.
Information on available filter cartridges and where to purchase them.
Details on EasyCare tab and adapter for cleaning processes.
Covers environmental conditions, electrical requirements, and water flow specifications.
Details cooling/heating capacity, compressor, coolant, and physical dimensions.
Lists common error codes displayed on the unit and their solutions.
Addresses problems like LED indicators, display errors, and program start failures.
Covers issues like low sparkling content, incorrect temperature, and spray patterns.
Guidelines for cleaning the unit's exterior, water lines, and recommended cleaning agents.
Information on finding and ordering spare parts via the BLANCO Shop.
Instructions for the correct disposal of electronic waste according to EU regulations.
Mentions compliance with directives and availability of conformity declarations.