Malfunctions
Malfunctions Possible causes Error correction
Blue LED on the mixer tap
is not lighting up
- Mixer tap is not receiving
electricity
- Connect the power supply unit for the control
box to the mains
- Check the connections on the control box
- The volume wheel is at “0” - Turn the volume wheel and set
an amount
>
“0”
Water does not run when
the sensor is activated
- Connecting hoses
arekinked
- Connecting hoses
arewrongly attached
- The volume wheel is at “0”
- Filter head is connected
against the flow direction
- Electronic devices are
infront of the sensor
- Connect hoses without kinks
- Connect the hoses according to
theassemblyinstructions
- Turn the volume wheel and set
an amount
>
“0”
- Check whether the filter head has been
connected against the flow direction, and
change the flow direction
- Remove electronic devices
Cold and/or warm water
is not running
- Connecting hoses
arekinked
- Connecting hoses are
wrongly attached
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
The set water quantity
for filter or hot water is
significantly dierent
- Malfunctions in the control
box
- Unplug the power supply to the control box,
wait for 1 minute, then plug it in again
38

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blanco drink.filter EVOL-S Pro and is the answer not in the manual?

Blanco drink.filter EVOL-S Pro Specifications

General IconGeneral
BrandBlanco
Modeldrink.filter EVOL-S Pro
CategoryPlumbing Product
LanguageEnglish

Related product manuals