EasyManua.ls Logo

Blastrac BDC-133M - Versions; EC Declaration of Conformity; Classification in Compliance with Standard en 60335-2-69 - Annexe Aa; Dust Emissions in the Environment

Blastrac BDC-133M
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.blastrac.eu ‒ info@blastrac.eu
3/18
Operating manual BDC-133M / BDC-133H
GB
Versions
WARNING!
Dust classication
Versions for dust harmful to health:
Classes M, H, the vacuum cleaner is suitable for use
with hazardous, non-combustible/non-explosive
dust in accordance with standard EN 60335-2-69,
Annexe AA.
Check the tolerated dust hazard class on the data
plate and on the label on the vacuum cleaner:
M (medium risk)
H (high risk)
[ NOTE ]
In the case of dust harmful to health, contact the local
health and safety authorities, and observe national
regulations in force both during use and disposal.
Radioactive substances are not included in the
denition of the type of dust harmful to health
described above.
EC Declaration of conformity
Every vacuum cleaner comes with a EC Declaration of
conformity. See fac-simile in g. 16.
[ NOTE ]
The Declaration of conformity is an important document
and should be kept in a safe place to be presented to the
Authorities on request.
Classication in compliance with
standard EN 60335-2-69 – Annexe AA
Vacuum cleaners for dust harmful to health are classied
according to dierent dust classication:
M (medium risk) suitable for separating dust with
an exposure limit value of no lower than 0.1 mg/m
3
,
depending on the volume occupied;
H (high risk) for separating all dust with an exposure
limit value lower than 0.1 mg/m
3
, depending on the
volume occupied, including carcinogenic and pathogenic
dusts, such as asbestos.
Dust emissions in the environment
Indicative values of performance:
Version for dust harmful for the health:
M: retains at least 99.9% of vacuumed particles (see
EN 60335-2-69, Annexe AA);
H: retains at least 99.995% of vacuumed particles (see
EN 60335-2-69, Annexe AA).
General recommendations
WARNING!
If an emergency situation occurs:
lter breakage
re outbreak
short-circuit
motor block
electric shock
etc.
Turn the vacuum cleaner o,
unplug it and request assistance
from qualied personnel.
WARNING!
The vacuum cleaners must not
be used or stored outdoors, or in
damp places.
They can be used for vacuuming
dry materials only.

Related product manuals