- 17 -
Suction and Discharge Operation
Turn the BLOOM on and observe the suction and discharge locations in the waterbody.
The intake should not create a vortex at the surface. If a vortex is visible, the suction
intake is not properly submerged. Verify that the suction is at least 2 ft beneath the
minimum water level. The bubble pattern visible at the surface of the water above the
discharge should consist primarily of small bubbles, roughly the size of a pea or smaller.
If bubbles are consistently larger than the size of a small pea, contact a Moleaer technical
service representative at (424) 558-3567.
Operating Parameter Ranges
Normal operating ranges for the BLOOM units are shown in Table 5.
Table 5. BLOOM Normal Operating Ranges
Parameter
BLOOM 25
BLOOM 50
BLOOM 150
Gas Pressure (Gauge)
40-120 psig
40-120 psig
40-120 psig
Liquid Pressure (Gauge)
10-20 psig
10-20 psig
10-20 psig
Gas Flow Rate (Standard)
(US) & (EU) (Rotameter)
0-2.5 CFH
0-5 CFH
0-10 CFH
If the BLOOM unit is consistently operating outside of the ranges shown in Table 4,
contact a Moleaer technical service representative at (424) 558-3567.