BL220 PERISTALTIC PUMPS
|
9
Parameter Description Default value Set value
P1
Measure type:
0 = pH with two decimal
1 = pH with one decimal
2 = Redox
0
P2
Level input:
0 = NO
1 = NC
0
P3
Storage of the ON/OFF
key status at shutdown:
0 = no
1 = yes
1
P4
Control type:
0 = OFF
1 = ON
2 = ON/OFF acid
3 = Proportional acid
4 = ON/OFF chlorine
5 = Proportional
chlorine
3
P5
Working threshold
0 to 14.0 (pH)
0 to 999 (mV)
7.00
P6
Hysteresis
0 to 2.00 (pH)
0 to 200 (mV)
0.40
P7
Delay at start-up
0 to 30 minutes
0
P8
Alarm delay
0 to 600 minutes
0
MEANING OF PARAMETERS
P1: This parameter allows to select the measurement type, pH or redox (mV). When setting P1=0
(pH reading with two decimal), please note that the two decimal places are visble only for
pH values below 10, because the display can show up to three digits. However, generally the
precision of pH measurements with one decimal is sufficient in most applications.