M2 OLED Tank Monitor Instructions
PN 1839
Installation Checklist
Check for components included
Read Warning and Cautions
Read QuickStart Installation Guide for mounting instructions
Read System Overview, Mounting Considerations, Detailed Wiring,
and Sensing Description
Read QuickStart Installation Guide for installation notes
Follow Initial System Setup instructions
Congure Displays
Congure Alarms
Congure Relays
Display Size 55mm x 28mm
Power Supply 7V–70V DC
Power Consumption 0.3W–1.0W*
* Variable with voltage, display intensity, and sleep mode
Regulatory
Monitor face is IP66 – protected against powerful water jets
when installed according to instructions
1839 Specications
Tanks
Senders North American 24033
European 10180
Blue Sea Systems Ultrasonic
Custom
Sender Resolution 1%
Custom Tank Shapes Auto Calibration
Warning and Caution Symbols
WARNING: The symbol refers to possible injury to the user or
signicant damage to the meter if the user does not follow the procedures.
CAUTION: The symbol refers to restrictions and rules with regard
to preventing damage to the meter.
WARNING
• If you are not knowledgeable about electrical systems, have an
electrical professional install this unit. The diagrams in these
instructions pertain to the installation of M2 Digital Meters and not
to the overall wiring of the vessel.
• If an inverter is installed on the vessel, its power leads must be
disconnected at the battery before the meter is installed.
• If an AC generator is installed on the vessel, it must be stopped
and rendered inoperable before the meter is installed.
• Verify that no other DC or AC sources are connected to the vessel’s
wiring before installing the meter.
CAUTION
The back of the unit is not waterproof. Do not install where the back
of the meter is exposed to water.
Components Included
M2 Head Unit Surface Mount Gasket
Mounting Ring
Surface Mount Bezel
and Seal
Mounting Nut
Flat Mount Bezel
Screwdriver
Retail Package Only
Connector
Bezel
Mount
Footer
Header
Carrier
Mount
#6-32 x 1/4"
Flat Head
Machine Screws
(4X)
#6-32 x 3/8"
Flat Head
Machine Screws
(4X)
Surface Mount Cover
Flat Mount Clamp
Panel
Frame
#8 x 1/2"
Flat Head Sheet
Metal Screws
(4X)
360 Panel Mounting Kit (PN 1525 sold separately)
1
Question and Answer IconNeed help?

Do you have a question about the Blue Sea Systems M2 OLED and is the answer not in the manual?

Summary

Specifications and Safety Information

Warning and Caution Symbols

Explains symbols indicating potential injury, damage, or operational restrictions for the meter.

Detailed Wiring Diagrams

Relay and External Component Connections

M2 Relay Connections

Explains how to connect external loads up to 0.5A using the internal MOSFET relay.

Meter Configuration

Alarm Setup and Control

Guides on setting high/low tank level alarms and configuring alarm delay.

Relay Setup and Control

Details configuring relay normal state, notifications, and silence options.

Tank Setup and Calibration

Explains enabling tanks, setting volume units, and selecting sender types.

Advanced Tank Configuration

Calibration and System Management

Using Auto-Calibrate

Explains the process for automatically calibrating tank sensor readings.

Software Upgrade Process

Upgrade via Software Upgrade Option

Steps for updating firmware using the setup menu and a USB memory stick.

Upgrade via Forcing Meter into Upgrade Mode

Procedure for updating firmware by forcing the meter into upgrade mode on startup.

Overview

The Blue Sea Systems M2 OLED Tank Monitor (PN 1839) is a digital monitoring device designed to track the levels of up to four tanks, providing high and low-level alarms for each channel. This device is suitable for marine electrical systems and offers various mounting and configuration options.

Function Description:

The M2 OLED Tank Monitor allows users to monitor tank levels, configure alarms, and manage relay outputs based on these levels. It supports different types of tank senders, including North American Standard, European Standard, and Blue Sea Systems Ultrasonic senders. The monitor displays tank levels as percentages, gallons, or liters, and provides a clear OLED screen for easy readability.

Important Technical Specifications:

  • Display Size: 55mm x 28mm
  • Power Supply: 7V-70V DC
  • Power Consumption: 0.3W-1.0W (variable with voltage, display intensity, and sleep mode)
  • Regulatory: Monitor face is IP66 rated, protecting against powerful water jets when installed correctly. The back of the unit is not waterproof and must be kept dry.
  • Tank Senders Supported:
    • North American Standard: Resistive type, 240-33 ohms (240 ohms indicating empty)
    • European Standard: Resistive type, 10-180 ohms (10 ohms indicating empty)
    • Blue Sea Systems Ultrasonic: Custom, uses sound waves to measure distance. Two types: 1800 for gasoline, 1810 for diesel, water, and waste.
  • Sender Resolution: 1%
  • Custom Tank Shapes: Auto Calibration
  • Connector Pin Assignment (8 Pin Connector):
    • Pin 1 (Required Connection): DC Negative
    • Pin 2 (Required Connection): DC Supply
    • Pin 3: Relay DC Out to Load
    • Pin 4: Relay DC +
    • Pin 5: Tank 1
    • Pin 6: Tank 2
    • Pin 7: Tank 3
    • Pin 8: Tank 4
    • USB: Micro USB Port (supports wire sizes from 16-26 AWG)
  • Relay Output: Internal MOSFET relay, drives external DC loads up to 0.5A. Protected by a thermally activated auto-resetting fuse. An inline 5A fuse is recommended for additional protection.
  • External LED Connection: Supports external LEDs (e.g., 8171). For systems >24V nominal, an additional 4K Ohms of resistance should be placed in-line.
  • External Alarm Connection: Supports external audible alarms (e.g., Floyd Bell Turbo Alarm 1070). Relay+ terminal can support 5-30V DC supply.
  • External Relay Compatibility: Can activate external relays (e.g., PN 7713, 12V or PN 7717, 24V Remote Battery Switch) for switching loads greater than 0.5A. Not compatible with 9012, 7700, 7701, 7702, & 7703 Remote Battery Switches.

Usage Features:

  • Installation:
    • Three mounting methods: surface mount, flat panel mount, and 360 panel mount.
    • Surface mount is waterproof to IP66; flat panel and 360 panel mounts are not waterproof and should not be used in exposed locations.
    • Requires all connections to the terminal block before connecting to the unit.
    • A fuse must be inserted into the in-line fuse holder on the positive (+) battery terminal as the final DC connection.
    • Safety Warning: Installation by an electrical professional is recommended for those not knowledgeable about electrical systems. Inverters and AC generators must be disconnected/stopped before installation.
  • User Interface:
    • OLED display shows Blue Sea Systems logo, serial number, and software revision on startup, followed by a System Summary screen.
    • Pop-up menu accessed by pressing any button.
    • Two-dimensional menu system navigated using UP/DOWN arrow buttons for summary information and NEXT button for detailed channel information or single parameters.
    • Setup menus accessed via the MENU button.
  • Alarm Setup & Control:
    • Configurable high and low tank level alarms for each channel.
    • Alarm thresholds can be set as percentages, gallons, or liters.
    • Alarm Delay (Tank Alarm Dly): Prevents false alarms due to tank sloshing by setting a delay timer (0-600 minutes).
    • When an alarm triggers, the buzzer sounds, the red ALARM LED lights, and the screen displays the alarm details. Pressing a button silences the buzzer, and another press returns to the previous display. The ALARM LED blinks until the condition is resolved.
    • Active alarms are indicated by flashing parameters in the display.
  • Relay Setup & Control:
    • Allows control of an external relay based on high or low tank levels.
    • Relay Normally On/Off: Sets the normal operating state (contacts closed/open).
    • Notification: Controls whether a notification is displayed when the relay activates.
    • Silence Relay: Allows the relay to deactivate after a user presses a key on the display, useful for silencing external buzzers.
    • Input Thresholds: Configurable Hi ON/OFF and Lo ON/OFF settings for each channel to prevent rapid toggling (cycling) of the relay.
    • Tank Relay Dly (Delay): Similar to alarm delay, prevents false relay activations due to tank sloshing.
  • Display Setup:
    • Brightness: Adjustable from 0% (dimmest) to 100% (brightest).
    • Sleep Timer: Sets the duration of inactivity (0-600 minutes) before the display turns off. Can be disabled (OFF).
    • Dim Timer: Sets the duration of inactivity (0-600 minutes) before the display dims. Can be disabled (OFF) or set to AUTO dim mode, where the display dims after two minutes in low ambient light.
    • Demo Mode: Displays factory-programmed values for commercial/promotional purposes. Alarms and relay settings still respond to actual measurements in Demo Mode.
  • Tank Setup:
    • Enable: Toggles display of tank and measurements. If OFF, the tank is not displayed, but alarms/relays remain active unless disabled separately.
    • Volume: Similar to Enable, toggles display of tank and measurements.
    • Show Percent: Displays tank values as a percentage (ON) or in gallons/liters (OFF).
    • Sender Type: Presets Resistance Lo and Resistance Hi values based on sender type (USA, Euro, 1810, 1811, Cstm).
    • Resistance Lo/Resistance Hi: Manually adjustable resistance values for empty and full tanks.
    • Tank Depth: Used with 1810/1811 senders, indicates tank depth in inches.
    • Tank Shape: Selectable shapes (Rect, Tri, Auto, Cstm). Auto appears after auto-calibration. Cstm indicates manual changes.
    • Custom Tank Shapes: Can be defined via Auto Calibrate or manually by entering parameters (Sensor 20%, 40%, 60%, 80%, 100% values).
    • Auto-Calibrate: Fills the tank at a constant rate to automatically determine calibration values. Requires sensor reading <15% initially.
  • Changing System Labels:
    • Allows users to change labels for each channel (max 16 characters, 11-12 displayed in summary screens).

Maintenance Features:

  • Software Upgrade:
    • Firmware can be updated via the Software Upgrade option in the Setup menu or by forcing the meter into upgrade mode on startup.
    • Requires a USB memory stick (Micro USB Host OTG) with the firmware file (image.xxxx.bin, where xxxx is the PN of the meter).
    • Caution: Removing power or the USB memory stick during the upgrade process will render the meter inoperable.
    • Upgrade messages provide feedback on success or errors (e.g., File Not Found, Corrupted File, No USB Device, Wrong Model Number, Wrong HW Version).
  • Version Info: Displays product name, serial number, and software version.