6. TROUBLESHOOTING
Problem Possible Cause Remedy
Power connection failure Check power cord and plug it in
Power switch is 'off' position Turn it to 'ON' position
Compressor (Freezer model only)
is not start Thermostat is 'off' position Reset it
Overload protector tripped Check the reason and correct
or replace O.L.P if necessary
Wiring is improper or loosed Check wiring against diagram
Control setting incorrect Reset the thermostat
Inadequate air circulation Rearrange products stocked to improve
air circulation
Door not sealing Check the sealing condition and correct it
The unit is not Refrigerant leak Check the leak part and repair / recharge
is not Fan motor defective Check and replace it
refrigerate well Not enough ventilation Move the unit in a well ventilated place
with at least 7inches of clearence
on all sides
Condenser is clogged Clean it
Thermostat defective Replace it
Not enough defrosts occuring
Evaporator a day operation in humid
is not defrost condition
completely Defrost heater defective Replace it
Wiring is improper or loose Check wiring against diagram
Poor sealing around Adjust and clean it
door gasket or replace it if necessery
Condensate Loading of too much warm or Cover products with vinyl wrap
water moist products
overflow Extreme enviroment
(i.e rainy season etc)