11
EN
BluFilter manual
The UV-C lamp with quartz glass (16-18) can be removed from the housing very easily by unscrewing
the case with a screwdriver. Then turn the head and dismantle the UV-c device.
1. Clean the quartz glass; unscrew the swivel and remove the glass from the housing Do not use
detergents, clean glass with a cloth or soft brush under running water. Dry the glass well on the inside
and reassemble.
2. The UV-C lamp should be replaced every season, or after 8,000 burning hours. The lamp still
burns after this period, but the UV-C radiation is minimal because the gas in the lamp is consumed.
Remove the lamp from the holder and fit new lamp.
6.C DISMANTLING AND CLEANING THE PUMP
The rotor with impeller can become fouled by lime-laden water. Lime deposits can block the pump if
cleaning is not done in time. Check this regularly, especially in the first months of use. The degree of
fouling depends entirely on water quality. If the motor is overloaded, the built-in motor protection will
switch off the pump, it can also switch on again after some time if the motor was too hot and has cooled
down again. If switching on and off continues, irreparable damage may occur to the engine.
1. Turn the pump housing counterclockwise one turn and remove from motor.
2. Clean the rotor under running water.
3. Clean the pump housing inside under running water.
7. WINTER PREPARATIONS
1. Remove the set from the water when frost approaches. Ice formation can cause irreparable
damage to the unit if the unit is not in operation.
2. Clean the set thoroughly as described in chapter 3-6
3. Check that the set and power cord are not damaged.
4. Store the set in a frost-free place in a bucket of water, this will prevent rubber rings from drying
out.
8. TROUBLESHOOTING
Observe safety instructions!
Problem Cause Solution
Pump does not work
No voltage Check mains voltage
Motor defective Replace the pump
Rotor blocked Clean rotor and filter material
Pump makes noise
Contamination in the pump
(pebble)
Open the pump and check for
contamination
Rotor and shaft worn Replace rotor and shaft
Little capacity
Impeller broken, or a connecting
tap is closed
Replace rotor with impeller,
open valve
Contaminated filter material Cleaning or replacing filter ma-
terial
Undervoltage Engage an installer
UV-C lamp does not work
UV-C lamp defective Replace the lamp
Lampholder defective Replace the lampholder
Can’t solve the problem yourself? Contact our helpdesk, we will be happy to help you. www.BluGarda.