EN
8
BluFilter manual
1. Remove filter cover as described above.
2. Open 2x locking screws. Remove the pump with UV-C device from the housing.
3. Open the pump coupling; the pump can be taken off the UV-C unit
4. Open the clip. The lamp housing with quartz glass can be rotated counterclockwise from the
holder.
Avoid direct contact with the lamp: hold UV-C lamp with a cloth
5. Clean quartz glass; unscrew swivel (4) and remove the glass from housing1. Do not use deter-
gents, clean glass with a cloth or soft brush under running water. Dry the glass well on the inside and
reassemble.
6. The UV-C lamp (8) should bereplaced every season, or after 8,000 burning hours. The lamp still
burns after this period, but the UV-C radiation is minimal because the gas in the lamp is consumed.
Remove the lamp from the holder (9) and fit new lamp.
Caution: position all sealing rings (5) and (7) in the right place during as-