EasyManua.ls Logo

BOC Edwards 412-J - Pump Lubrication and Initial Fill

BOC Edwards 412-J
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
J SERIES M ICROV A CJ SERIES M ICROV A C VA CUUM PUM P V A CUUM PUM P
PAGE 2 -5
protection, containing detergent dispersants, with excellent flow characteristics at low temperature. It has a
viscosity of 430 SSU at 100 Deg. F. (38 Deg. C), and 82 SSU at 210 Deg. F. (99 Deg. C), w ith a vapor
pressure of 0.0001 mm Hg. at 145 Deg. F. (63 Deg. C)
If the pump is to be operated at vacuum levels that cause the oil temperature to exceed 160 Deg. F. (71 Deg. C)
for extended periods of time, a heavier grade oil should be used. Stokes V-Lube (Label G) is available for oil
temperatures up to 200 Deg. F. (94 Deg. C).
Special operating conditions may require the use of special oils. Consult Stokes Vacuum for specific
recommendations w hen other than regular petroleum oils are being used.
2.6.12.6.1 INITIAL FILLINITIAL FILL
The Microvac pump is shipped w ith an initial charge of oil, (4 gallons)(15 L) for the 212J and (12
gallons)(45 L) for the 412J, in the reservoir. Before connecting the suction manifold slow ly rotate
the pump thru two revolutions. This will distribute the oil throughout the pump interior.
CAU TION:CAU TION: STARTING THE MICROVAC PUM P WHEN OIL TEM PERSTARTING THE MICROVAC PUM P WHEN OIL TEM PERATURE IS BELOW 55ATURE IS BELOW 55
DEG. F., (13 DEG. C) CAN RESULT IN EXCESSIVE WEAR AND GALLING DAM AGE TODEG. F., (13 DEG. C) CAN RESULT IN EXCESSIVE WEAR AND GALLING DAM AGE TO
THE M OVING PARTS.THE M OVING PARTS.