─ 32 ─
3. TREADMILL ERROR MESSAGES
3.1 Communication Error message: ER01
3.1.1 Check console and the main communication cable connection;
3.1.2 Check inverter and the main communication cable connection;
3.1.3 Replace inverter;
3.1.4 Replace console.
3.2 Elevation Error messages: ER02
3.2.1 Check power cable of actuator and inverter connection;
3.2.2 Check cable of sensor of actuator and inverter connection;
3.2.3 Replace actuator;
3.2.4 Replace inverter.
3.3 Safe-key Error message: ER03
3.3.1 Check safe-key button;
3.3.2 Check cable of safe-key;
3.3.3 Replace safe-key PCB;
3.3.4 Replace console.
3.4 Over current message: ER04
3.4.1 Add silicon to run belt and board;
3.4.2 Replace inverter;
3.4.3 Replace motor.
3.5 Lower voltage message: ER05
3.5.1 Check power AC 200-240V (105-125V).
3.6 Over load message: ER06
3.6.1 Add silicon to run belt and board;
3.6.2 Replace run belt and board;
3.6.3 Replace inverter;
3.6.4 Replace motor.
Console Panel Functions