3.7 Emergency stop message: ER07
3.7.1 Reset Emergency switch then press STOP button;
3.7.2 Check cable of Emergency switch and Emergency switch connection;
3.7.3 Replace Emergency switch;
3.7.4 Replace inverter.
3.8 The console no power
3.8.1 Check the AC power;
3.8.2 Turn on the power switch;
3.8.3 Check the communication cable and console connection;
3.8.4 Check the communication cable and inverter connection;
3.8.5 Replace the communication cable;
3.8.6 Replace the power cable.
Console Panel Functions