    criggsAug 10, 2025
    How to troubleshoot Sedimentor purification performance issues in Bohle Sedimentor 0.3 Water Filtration Systems?
    • J
      josephschmidtAug 10, 2025
      If the Sedimentor in your Bohle Water Filtration System isn't showing purification performance, first ensure the sedimentor is switched on. If it is on, the amount of sedimentation granules might be too low; try increasing the dose quantity. Also, check that the cycle time isn't set too high and reduce it if necessary. Finally, verify the function of the waste water pump. Remove any blockages, replace the pump if needed, use a stronger pump, or change the pump's position in the waste water tank.
  • R
    ricky68Aug 15, 2025
    What to do if the filtered water is not pumped back in Bohle Sedimentor 0.3 Water Filtration Systems?
    • A
      Alexandra WaltersAug 15, 2025
      If the filtered water is not pumped back in your Bohle Water Filtration System, start by checking if the main switch is turned on. If it is on, the pump might be defective and needs replacement. Alternatively, the float switch could be defective and also needs replacement.
  • A
    Amy MorganAug 19, 2025
    What to do if there is no transfer of sludge and water to the filter bag in Bohle Sedimentor 0.3 Water Filtration Systems?
    • B
      Brian CurtisAug 19, 2025
      If there is no transfer of sludge and water to the filter bag in your Bohle Water Filtration System, the sedimentor outlet might be clogged, or the drain flap isn't opening. Try removing any blockages. Open the compressed air and repeatedly activate the drain flap.
  • M
    Mr. Alexander GarciaAug 26, 2025
    Why are sedimentation granules not being taken from the container in Bohle Water Filtration Systems?
    • R
      Robert JohnsonAug 26, 2025
      If sedimentation granules are not being taken from the container in your Bohle Water Filtration System, the container outlet may be clogged. Clean the container outlet. Also, check the drive/shaft coupling for correct positioning and adjust if necessary, if the drive is not connected to the screw conveyor.
  • T
    timothy37Aug 30, 2025
    Why is the filter bag not draining properly in Bohle Sedimentor 0.3 Water Filtration Systems?
    • M
      Megan GarciaAug 30, 2025
      If the filter bag in your Bohle Water Filtration System does not drain properly, it is likely that the pores of the filter bag are clogged, and you should exchange the filter bag.
  • M
    mwhiteheadSep 4, 2025
    Why are sedimentation granules swimming on the water surface in Bohle Sedimentor 0.3?
    • E
      Erin GriffithSep 4, 2025
      If sedimentation granules are swimming on the water surface in your Bohle Water Filtration System, it indicates a slight overdosage. Progressively reduce the amount of sedimentation granules.