23
en
REPLACE THE UV LAMP
ABOUT THE UV LAMP
The UV lamp is a consumable and must be replaced
after a certain amount of time. The Therapure TP350
has an internal timer. After an operating time of
12,000 hours, the appliance alerts you to the up-
coming lamp change with the UV warning on the
display:
If you continue to use the spent UV lamp for a
longer time, the eectiveness of the disinfec-
tion will decrease significantly.
REMOVING A USED UV LAMP
1. Disconnect the Therapure TP350 from the power
outlet.
2. Open the rear cover.
3. Wait 5 minutes and let the used UV lamp cool
down.
4. Remove the filter.
5. Unscrew the four screws to remove the cover of
the UV lamp.
6. Pull the UV lamp out of the housing.
7. Open the clip on the cable to disconnect the UV
lamp from the appliance.