aquaProp–SCOOTER
Instruction for use
Version : SG 2015-11 Page | 18
15. Troubleshooting
In case of malfunctions or failure, the table below presents a list of the most typical problems.
Fault Cause of failure Remedy
Scooter doesn’t operate
>Battery plug not connected >Connect
>Battery empty >Recharge battery
>step switch to „Off“ >Switch step switch to „On“
>Reed Sensor defect >Replace the Reed Sensor
>Step switch defect >Replace the switch unit
>Cable break >Replace cable / switch unit
>Motor defect >Replace motor
Speed adjustment doesn’t work
>Switch unit defect >Replace switch unit
Scooter immediately starts
after switching „ON”
>Step switch to „1“ or „2“ >Release drive switch
+ press drive switch >Leg spring defect
After starting the drive >Battery voltage too low >Recharge battery
stops immediately >overheated drive >cool down
Loading control on the loader does
not light
>No power at outlet >Choose a different outlet
>Not connected charging plug >Insert the plug
>Defekt in the charger >Return to manufacturer
>Defekt in the battery >Return to manufacturer
Inrush of water
>Leakage of O-rings >Replace O-rings
>Leakage of slide ring sealing >Replace sealing
>Fracture of scooter housing >Return to manufacturer
Switch sluggish >Dirt sand on the axis
> Rinse with water and
>oil axle afterwards
Housing, tube >Clean grooves
sluggish >O-rings soiled >Clean O-rings / Replace
>Maintain scooter housing with silicone
Scooter has >Battery capacity too low >Replace battery
reduced power >Propeller defect >Replace propeller
Propeller jumps from the drive shaft
>Motor runs in the wrong direction
>On top of the motor, there ar 3 cables
with connectors. Swap 2 of them.
Scooter doesn’t reach full runtime
>Battery has not, or only partially
loaded.
>Battery was too warm. Let the battery
cool down before charging.
>Recharge the battery again.
>too high resistance >Improve your swimming position
>Customize your gear on
When driving at level 2, the motor
controls down
>The temperature controller regulates
down to level 1
>If the engine has cooled down, the
controller returns up automatically to
step 2.