EasyManua.ls Logo

Bonex ECOS - 12 Maintenance and Care; Maintenance Intervals of Bonex-Scooter

Bonex ECOS
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BONEX-SCOOTER
Instruction for use
Version: 2016_08 Page 27
12. Maintenance and care
Rinse the scooter with fresh water after every dive, especially after using it
in salt water or brackish water. The outside of the scooter can be cleaned
with mild soapy water. A toothbrush can also be used to get into
inaccessible places. After being used several times the aluminium housing
should be sprayed with a thin viscous silicone spray. This closes the fine
pores and protects against dirt and corrosion.
The propeller should be removed after using in salt water. While watching
from shroud side, turn the prop nut clockwise to release it. Wash the
propeller and drive shaft with fresh water and spray with a silicone spray.
After longer use, the spring of the sliding ring seal should be removed and
its O-rings greased.
12.1 Maintenance intervals of Bonex-Scooter
Maintenance point Interval
To be
done by
Oil housing with silicone Occasionally Diver
Visually inspect battery and cable Before every dive Diver
Oil rotary switch Occasionally Diver
Change housing O-rings Annually Diver
Change scooter nose O-rings Every 2 years Diver
Change O-rings axles / shaft Every 2 years Diver
Change sliding ring seal Every 5 years Diver
Change pressure disk As required Diver
Check cable for breaks Annually Diver
Check propeller for wear Occasionally Diver
Check housing for wear Occasionally Diver
Renew battery Appr. 500–1000 cycles
Diver
Performance upgrade
(Motor performance curve)
As required Bonex
Pressure and performance test All 2 years Bonex