VG4 Modular Camera Series Installing Roof Parapet and Pipe Mounts | en 59
Bosch Security Systems, Inc. Installation Manual F.01U.216.010 | 8.0 | 2011.02
6. Apply the supplied thread sealant to the threads on the Pipe.
Make sure all surfaces are clean and dry.
Apply a bead of sealant completely around the leading threads of the male fitting.
Force the adhesive into the threads to thoroughly fill all voids.
7. Thread the Pipe Cap onto the down pipe and tighten securely to prevent leaks. See
Figure 3.9, Page 58.
3.7 Wire the Pipe Interface Board
This section provides instructions for connecting wires and cables to the Pipe Interface
Board, as illustrated below. See Section 5 Cable and Wire Standards, page 88 for cable and
wiring recommendations and specifications.
Figure 3.10 Pipe Interface Board Connections
WARNING!
You must thread the Dome Cap onto the pipe until it is tight. Failure to do so can result in
damage or serious injury or death.
BNC
7
5
6
4
3
2
1
2
1
2
1
3
J102
P107 P101
P102
P103
P104
P106
J101
AGND
A7
A6
A5
A4
A3
AGND
OUT 3
OUT 2
OUT 1
1
2
3
4
5
6
P105