Appliance details
11
830 ES – 6 720 644 936 (2021/08)
Table 3
If appliance is installed at elevations above 2000ft, refer to
chapter 4.3.8 Fan speed adjustment.
Safety devices
Flame failure device (ionization flame rod sensor)
Overheat prevention (temperature limiter)
Inlet temperature sensor
Outlet temperature sensor
Back flow temperature sensor
Voltage
Nominal V AC 120
Frequency Hz 60
Amperage
Idle mA 40
Operation A 2.5
Noise db (A) 45 - 65
Water protection
3)
IP X4D
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.14, page 46.
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
3) Protection against water drops.
Technical characteristics Units 830 ES