Installation instructions
830 ES – 6 720 644 936 (2021/08)
32
Adjusting minimum power fan speed (P2)
To select fan speed:
Push power button to shut the water heater off.
Push and hold the button.
Turn power back on by pushing the power button .
Continue to hold the button until all symbols on the
screen light up and the temperature reads 188 °C.
When display reads 188, immediately release the
button.
The display should now read P2.
Press to enter P2 adjustment. The current setting will
appear on the display (factory default).
Press or to choose the fan speed suitable with
your installation, see table 23 and 24.
Press and hold (± 5 sec.) “Program” button until the
display flashes, then the selected value is memorized.
Proceed directly to chapter 7.4 to confirm CO
2
values are
within range.
Adjusting maximum power fan speed (P1)
To select fan speed:
Push power button to shut the water heater off.
Push and hold the button.
Turn power back on by pushing the power button .
Continue to hold the button until all symbols on the
screen light up and the temperature reads 188 °C.
When display reads 188, immediately release the
button.
The display should now read P2.
Press the minus button to display P1.
Press “Program” button to enter P1 adjustment. The
current setting will appear on the display.
Press or to choose the fan speed suitable with
your installation, see table 23 and 24.
Press and hold (± 5 sec.) “Program” button until the
display flashes, then the selected value is memorized.
Proceed directly to chapter 7.4 to confirm CO
2
values are
within range.
P
P
P
P
P
P
P
P
P
+
P