AVENAR detector 4000
FAP-425 / FAH-425
en Operation Guide
Question and Answer IconNeed help?

Do you have a question about the Bosch AVENAR FAP-425 and is the answer not in the manual?

Summary

Product Description

System Overview

Functional Description of Sensor Technology

Details the operational principles of the optical, thermal, and chemical sensors used in the detector.

Detector Features

Lists key features such as self-monitoring, adjustable sensitivity, EMC safety, and LSN loop functions.

Planning

Basic Installation and Configuration Notes

Provides guidelines for planning multi-sensor fire detectors, including monitoring area and installation height.

Programming

Programming FAP-425-DOTC-R

Explains programming for the FAP-425-DOTC-R, including selectable installation locations and sensitivities.

Connection

Detector Connection

Illustrates connection points and provides a notice regarding shield wire insulation.

Detector Removal

Details the procedure for disassembling unlocked and locked detector heads from the base.

Address Setting

Explains how to set addresses using rotary switches for automatic or manual allocation.

Maintenance and Service

Test Instructions for LSN Detectors

Provides procedures for testing LSN improved fire detectors, including revision mode and walktest.

Test Instructions for Specific Detector Models

Details sequential and simultaneous walktests for specific multisensor detector models.

Technical Data

Summary

Product Description

System Overview

Functional Description of Sensor Technology

Details the operational principles of the optical, thermal, and chemical sensors used in the detector.

Detector Features

Lists key features such as self-monitoring, adjustable sensitivity, EMC safety, and LSN loop functions.

Planning

Basic Installation and Configuration Notes

Provides guidelines for planning multi-sensor fire detectors, including monitoring area and installation height.

Programming

Programming FAP-425-DOTC-R

Explains programming for the FAP-425-DOTC-R, including selectable installation locations and sensitivities.

Connection

Detector Connection

Illustrates connection points and provides a notice regarding shield wire insulation.

Detector Removal

Details the procedure for disassembling unlocked and locked detector heads from the base.

Address Setting

Explains how to set addresses using rotary switches for automatic or manual allocation.

Maintenance and Service

Test Instructions for LSN Detectors

Provides procedures for testing LSN improved fire detectors, including revision mode and walktest.

Test Instructions for Specific Detector Models

Details sequential and simultaneous walktests for specific multisensor detector models.

Technical Data

Bosch AVENAR FAP-425 Specifications

General IconGeneral
Detection principleOptical
Quiescent current @ 24 VDC≤ 0.5 mA
Operating temperature-10 °C to +55 °C
Air humidity≤ 95% (non-condensing)
Protection categoryIP40
Weight0.15 kg
ApprovalsEN 54-7