Figure 18.2: Detailed Rothenbuhler 5110_4001-42 High Security Bell to control panel wiring (B5512 shown)
1 á…³ 5110 Logic Board
8 á…³ Alarm input point*
2 ᅳ 4001-42 External Line Balancing Module 9 ᅳ 10 kΩ resistor
3 á…³ Control panel set to OUTPUT A using AUX
PWR
10 á…³ Optional silence switch
4 á…³ Alarm output 11 á…³ D133 Relay Module
5 á…³ Alternate alarm (use B or C) 12 á…³ BBL In 4
6 á…³ Common 13 á…³ BBL Out 5
7 á…³ +12.0 VDC 14 á…³ Terminal TB1
*
Use Terminals 1 through 8. (Select only one.)
Notice!
Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault
applications.
System configuration requirements
The following configuration and programming options are required for UL Bank Safe and Vault
Systems. Refer to RPS Help or the control panel's Program Entry Guide for programming
information.
92 en | Approved applications Control Panel