14
2 Safety
Before use your charger, please read all instructions carefully.
I
CAUTION
If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent in order to avoid a hazard.
Disconnect the supply before making or breaking the connections to the battery.
The battery connection, which is not connected to the vehicle body, must be connected

from battery and fuel lines. Only then connect the battery charger to the mains supply.
After charging, disconnect the battery charger from supply mains. Then remove the
chassis connection and the battery connection, in this order, the conductor to be
connected to the positive pole shall be colored red and that to be connected to the
negative pole shall be colored black.
I
WARNING

towards the supply mains to protect the users from electric shock.
I
WARNING
Explosion hazard and re hazard!
Explosive gases.

Provide adequate ventilation during charging.
Battery
Used for 12 V 1.2 Ah - 120Ah LiFePO and Lead-Acid type (WET, EFB, GEL, AGM, open
and VRLA), or 6 V 1.2 Ah - 14 Ah Lead-Acid type (WET, EFB, GEL, AGM, open and
VRLA) rechargeable battery.
I
WARNING
Do not attempt to charge a non-rechargeable battery!
Keep children and others away from charger.