Charger Bosch C40-Li I Operating instructions EN
18
(6 V or 12 V) in a complex measuring procedure.
After 1-3 minutes, the charger will detect whether the battery is a 6 V or 12 V battery
and switch to the appropriate 6 V mode or 12 V motorcycle mode.
4.6 Override Mode
If the charger detects that the connected battery is a 6 V battery and enters 6 V mode,
but the user is very sure that it is a 12 V battery, the user can press and hold the mode
button for 5 seconds to switch the charger to any 12 V charging mode.
I
CAUTION
Please only use this override mode if you are sure that the battery to be charged is a
12 V battery. The 12 V mode can charge the battery already from 3.75 V low voltage.
Therefore, a 6 V battery could be overcharged and further dangers (increased gas
4.7 Device protection function
In the event of a short circuit on the charging cable, the fuse (5b) on the charging
cable prevents damage to the device and the electrical system.
5 Maintenance and care
Always unplug the mains connector before cleaning the charger.
The device is maintenance-free.
1. Turn off the device.
2. Use a dry cloth to clean the plastic surfaces of the device.
3. Never use solvents or other aggressive cleaning agents.
4.
order to maintain operational safety.
5. For 24 V battery, please use C70.
For EU Version:
Robert Bosch GmbH
Auf der Breit 4
76227 Karlsruhe
Phone: +49 0391 832 29671
E-Mail: kundenberatung.kfztechnik@de.bosch.com
For UK version:
Robert Bosch GmbH
Broadwater Park,
Uxbridge UB9 5HJ
Phone: 0344 892 0115
E-Mail: contact@uk.bosch.com