2.8 Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
unit is hermetically sealed. The following information on the refrigerant
complies with the requirements of EU Regulation No. 517/2014 on
fluorinated greenhouse gases.
Notice for the user: If your installer adds refrigerant, he enters the added
fill volume and the total amount of the refrigerant in the following table.
Table 39 F-Gas
3Operation
3.1 Indoor unit overview
Key to Fig. 1:
[1] Air inlet
[2] Electric control box
[3] Air filter
[4] Air Outlet
3.2 Indoor unit display
Key to Fig. 3:
[1] Manual operation
[2] Status indicator
[3] Timer indicator
[4] Pre-heating and defrosting indicator
[5] Alarm indicator
[6] Infrared signal receiver
[7] LED indicator
The operating modes can be selected in the sequence automatic mode,
cooling mode and shutdown via the Manual operation key.
Manual button
Table 40 Indications on the display unit
3.3 Overview wired room controllers
Keys of the wired room controller
Key to figure 3:
[1] Receiver for infrared remote control
[2] Display of the wired room controller
[3] Keys of the wired room controller
Table 41 Keys of the wired room controller
Product type Rated cooling
output
[kW]
Rated heating
output
[kW]
Refrigerant
Type
Global
warming
potential
(GWP)
[kg Co
2
equ.]
CO
2
equivalent
of initial
charge
Initial
charge
volume
[kg]
Additional fill
volume for
pipe length
L
1)
[g/m]
1) Total pipe length L in metres (if L > 5 m simple path from outdoor unit to indoor unit).
Total charge
volume during
commissioning
[kg]
CL5000L 35 E 3.52 3.81 R32 675 0.49 0.72 12
CL5000L 53 E 5.28 5.57 R32 675 0.78 1.15 12
CL5000L 70 E 7.03 7.62 R32 675 1.01 1.5 12
CL5000L 88 E 8.79 9.38 R32 675 1.35 2.0 24
CL5000L 105 E 10.55 11.72 R32 675 1.62 2.4 24
CL5000L 105 E-3 10.55 11.72 R32 675 1.62 2.4 24
CL5000L 125 E 12.02 13.48 R32 675 1.89 2.8 24
CL5000L 140 E-3 14.07 16.12 R32 675 1.96 2.9 24
CL5000L 160 E-3 15.24 18.17 R32 675 2.03 3.0 24
Operating
Mode
Display Display output
Automatic
mode
Operation indicator
on
Cooling and heating modes: Set
temperature
Fan only mode: Indoor ambient
temperature
Manual cooling
mode
Status indicator
flashes
The system automatically
switches to automatic mode after
30 minutes of forced cooling.
The remote control is deactivated
during forced cooling.
Shutting-down All indicators off If the display is switched off, the
indoor unit switches off and the
remote control is reactivated.
Key Function
K Switch on/off.
M Set operating mode.
DAYOFF Day off/deletion.
. / Adjust up/down setting.
Confirm choice.
TIMER Set timer.
Fan step
d Navigate back.
No function.
FUNC. Set function.
COPY Copy/adopt data.
Operating
Mode
Display Display output