21
Condens 5000 W – 6720644144 (2019/03)
Operation
4.3 Starting the central heating
The maximum flow temperature can be matched to the heating system by the flow
temperature controller. The current flow temperature is shown on the display.
Setting on flow
temperature controller (
Flow temperature Sample application
1 Approx. 35 °C
2 Approx. 43 °C
3 Approx. 50 °C Underfloor heating
system
4 Approx. 60 °C
5 Approx. 67 °C
6 Approx. 75 °C Radiator heating system
max. Approx. 90 °C Convector heating
system
Table 3
With underfloor heating systems, take care to observe the
maximum permissible CH flow temperatures.