D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 67
Bosch Security Systems | 5/05 | F001U003636B
L## Change Relay
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
28 Change Relays [COMMAND][5][4]
Manually activate or reset a system relay.
Do not use the Chg Relays? function to
toggle relays reserved for special functions.
Special function relays are Area and Panel
Wide Relay functions as well as relays
assigned to CC# Entr Key Rly?
L## Remote Program
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
29 Remote
Programming
[COMMAND][4][3]
Start a remote programming software (RPS) session
when the phone rings at the control panel.
L## Move to Area
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
30 Move to Area [COMMAND][5][0]
Temporarily switch to a different area and perform
keypad functions related to that area.
L## Display Rev
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
32 Display Software
Revision
[COMMAND][5][9]
Display the control panel model name and software
revision. For example:
9412GV2 REV ##.##
L## Service Walk
Default: Refer to the program record sheet
Selection: Blank or E
Function No. Function Name Alternate Keystroke
33 Service Walk Test (Menu function only)
Start a Service Walk Test for all 24-hour Interior or
Perimeter Controlled points in the control panel.
Points are not included in this test if:
• Points are in an area that is already in a Walk Test
Mode.
• Points are assigned to an area that is not enabled
A# Area On
.
• Points are in an area that is Master or Perimeter
armed.
• A Service Walk Test is initiated, and one person
can test all the points in the control panel without
assistance. The following features are provided
with the Service Test Mode:
- Display indicates exactly how many points
can be tested.
- Battery and bell tests do not occur during this
Walk Test.
- The test ends when all points are tested or the
test times out after 20 minutes of inactivity.
- Events print locally without alarm
annunciation or reporting to the central station
receiver.
- D1255 Keypad displays a sequential count
and the text for the point after each point is
activated and restored.
- The D1255 Keypad displays ALL PNTS
TESTED.
- If enabled in Routing, Service Start and
Service End are reported at the central station
receiver for the beginning and end of the test.
Point 128 and Point 248 appear as missing. This is
normal. These points are used for supervising the
Zonex 1 bus (Point 128) and Zonex 2 bus (Point 248).
If the Zonex bus has a fault, these points indicate a
short.
This function allows viewing of extra points. Extra
points occur under two conditions: an extra point is
wired electrically to the Zonex bus with a blank
P###
Point Index
, or two Zonex devices exist for the same
Zonex address.