Follow all instructions and warnings for batteries. Do not short terminals, charge alkaline batteries, mix old/new, or mix chemistries.
Use only recommended accessories and have repairs performed by qualified personnel to avoid serious injury.
Use AA alkaline batteries. Ensure correct polarity. Monitor battery status via indicator b. Replace batteries in pairs.
Slide the leg extension 17 onto the fold-out leg 1 from the front, securing it over the joint.
Protect from moisture, sun, and extreme temperatures. Allow acclimatization. Follow initial setup guidelines.
Use button 12 to turn on/off. Auto-shutdown after 30 min. Last value is saved when 'H' indicator appears.
Use spirit levels 8/9 for alignment. Use button 13 to rotate display for better readability.
Place legs on surfaces to measure. Lock position with knob 3. Use legs as a straight edge to transfer angles.
Press 'HOLD' button 11 to save current value. 'a' indicator flashes. Stored value is overwritten by new value.
Open legs to desired spring angle. Measure or set angle. Angles > 90° are converted. Use 'HOLD' to recall saved angle.
Place legs flat against walls to measure or set corner angle. Used for fitting workpieces into corners.
Press button 15 to calculate and display 'MTR' (miter) and 'BVL' (bevel) angles for compound cuts.