16 | English
1 609 92A 3MW | (21.11.16) Bosch Power Tools
Briefly press the measuring but-
ton 2 to initiate the measurement.
The current measured value c ap-
pears in the bottom line of the dis-
play. The laser beam is switched
off.
To switch on the laser beam, brief-
ly press the measuring button 2.
To initiate another measurement,
briefly press the measuring but-
ton 2 again. The current meas-
ured value c is displayed in the
bottom line. The previous meas-
ured value b is displayed in the middle line. In the top
line, the auto-sum a (the sum of the current and previ-
ous measured value) is displayed.
Changing the Unit of Measure
Switch the measuring tool off.
Press and hold the
measuring button 2.
When the cursor is on
the desired setting, re-
lease the measuring
button 2. After releasing, the measuring tool switches
itself on with the selected setting.