6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Installation instructions | 17
4.6.2 Approved vent components and terminations
Manufacturer
Manufacturer part number
Product description
Diagram
Horizontal
Vertical
Equivalent Lengths (Ft.)
Bosch 196050
196051
196052
2" Bird screen
3" Bird screen
4" Bird screen
hh 2
- - 2", 3", and 4" SCH40 (Solid Core) PVC/CPVC
45° long sweep elbow
h h 2.5
- - 2", 3", and 4" SCH40 (Solid Core) PVC/CPVC
45° short sweep elbow
hh 2.5
- - 2", 3", and 4" SCH40 (Solid Core) PVC/CPVC
90 ° short/long/extra long, sweep elbow
1)
h h 5
- - 2", 3", and 4" SCH 40 (Solid Core) PVC/CPVC
"T" terminal w/vent screen
hh 10
- - 2", 3" and 4" SCH40 (Solid Core) PVC/CPVC
straight pipe
h h 1
IPEX 196005 PVC Concentric termination (2" by 16" long) hh Exhaust:
1.5
Intake: 20
IPEX 196105 PVC Concentric termination (2" by 28" long) h h Exhaust:
2.5
Intake: 20
IPEX 196125 PVC Concentric Termination Kit (2" by 40" long) hhExhaust: 3
Intake: 20
IPEX 196006 / 197009 PVC / CPVC Concentric Termination Kit
(3" by 20" long)
h h Exhaust:
1.5
Intake: 40
IPEX 196106 / 197107 PVC / CPVC Concentric Termination Kit
(3" by 32" long)
hhExhaust: 2
Intake: 40
IPEX 196116 / 197117 PVC / CPVC Concentric Termination Kit
(3" by 34" long)
h h Exhaust: 2
Intake: 40
IPEX 196021 / 197021 PVC / CPVC Concentric Termination Kit
(4" by 36" long)
hhExhaust: 2
Intake: 60
Table 6 Approved PVC/CPVC Vent Components & Terminations