EasyManua.ls Logo

Bosch Greentherm T9800 SEC 199 - Information;Adjustments Menu

Bosch Greentherm T9800 SEC 199
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Operating Instructions | 43
6.5 Information /Adjustments menu
Access to Information / Adjustments menu
Display shows the set point temperature.
Touch the symbol .
Display shows P4 Information.
Touch symbols or to scroll through the available
menus.
Available menus
6.5.1 “P4” - Information
Fig. 43 P4 - Information
This menu provides access to several parameters.
Access to information / adjustments menu.
Display shows P4 Information.
Touch the symbol .
Display shows DH Data History.
Touch the symbols or to choose the following
information.
DH Data History
OD Operation Data
FH Failure History
AC Consumptions
HS About
Touch the symbol to selected the desired
information.
DH Data History
Allows you to view two parameters:
Operation Cycles - number of times burner has been
started.
Operation Hours - number of hours burner has been
operational.
OD Operation Data
Allows you to view various parameters of the current operation
of the appliance:
Hex Out NTC - current water temperature at heat
exchanger outlet.
Inlet NTC - current temperature of the temperature sensor
of the water inlet tube.
Outlet NTC - current temperature of the temperature
sensor of the water outlet pipe.
Fan Speed - current fan speed.
Water Flow - total flow, through main valve + bypass.
Output Power - % current power.
Ambient NTC - current temperature inside cabinet near
the fan.
Exhaust Gas NTC - Exhaust flue gases temperature sensor.
SS Hex NTC - Flue gases temperature sensor at the
condensing unit inlet (between heat exchangers).
Ambient NTC - current temperature inside cabinet near
the fan.
External Tank - current temperature on the external tank.
Barometric pressure - current barometric pressure at
installation location.
ION - current ionization value.
FH Failure History
Allows you to view the last 10 error codes.
Touch the symbol .
Display shows the last 10 error codes.
If the display shows ellipsis (...) means that no error as
occurred.
Touch symbols or to navigate between errors.
Touch the symbol to see the date and hour when the
error occurred.
Touch the symbol to return to main menu.
AC Consumption
Allows for displaying, in graphic form, the consumption of gas
and water for the last 5 operations longer than 1 minute.
HS About
Allows you to view the versions of software / hardware installed
on the water heater.
6.5.2 SA - Settings
Only to be use when domestic recirculation is installed.
Display Description
P4 Information (section 6.5.1)
SA Settings (section 6.5.2)
AU Technical Settings [service mode] (section 6.5.3)
P9 Purge (section 6.5.4)
Table 20

Table of Contents

Related product manuals