EasyManua.ls Logo

Bosch Greentherm T9800 SEC 199 - Page 47

Bosch Greentherm T9800 SEC 199
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Operating Instructions | 47
Touch symbols or to select AU Technical
Settings menu.
Touch the symbol .
Display shows Technical Settings menu (password input).
Select the password. The password is 1886.
Technical Settings completed.
Touch the symbol .
Access to installer exclusive menus.
P7 - Gas Type (LPG, NG)
LM - Temperature Limited
RS - Recirculation Settings
CA - Combustion Adjust
PA - Water Actuator
PF - Bypass Valve
PE - Appliance Type
AB Region Selection
A4 Demonstration
P7 - Gas Type (LPG, NG)
For more information,
▶See section6.8.
LM Temperature Limited
Unlock the Temperature Limit
Touch the symbol .
Display shows following menu.
Unlocked
–Locked
The current selection is in green color.
Touch symbols or to select Unlocked.
Touch the symbol .
Touch the symbol to return to main menu.
RS Recirculation Settings
To define recirculation comfort level,
Touch the symbol .
Touch symbols or to define comfort level.
1
2
–...
9
Choosing a higher comfort level (9) will set the
recirculation water temperature closer to the set point
defined on the water heater. Choosing a lower value (1) will
favor efficiency at the expense of recirculation temperature
comfort.
Touch the symbol .
Touch the symbol to return to main menu.
CA Combustion Adjust
For more information,
See section 8.11.
PA Water Actuator
For more information,
See section 6.7.
PF Bypass Valve
To Enable or Disable bypass function.
Touch the symbol .
Display shows following menu.
Off
–On
The current selection is in green color.
Touch symbols or to select the desired option.
Touch the symbol .
Touch the symbol to return to main menu.
PE Appliance Type
This menu shows the technical specifications of the appliance.
AP Appliance Power
ML Model
TP Type
AP Appliance Power
Touch the symbol .
Display shows appliance power (default set).
199K BTU
or
160K BTU
Touch the symbol to exit.
Touch symbols or to scroll through other menus.
ML Model
Touch the symbol .
Display shows appliance model.
Indoor
or
Outdoor
Touch the symbol to exit.
Touch symbols or to scroll through other menus.
TP Type
Touch the symbol .
Display shows appliance model.
Residential
or
Commercial
Touch the symbol to exit.

Table of Contents

Related product manuals