Problem solving
Greentherm T9800 SEO 160/199 | SECO 199 – 6 720 817 281 (2018/12)
46
CA Water flow above 9.2gpm. Disconnect the appliance and purge hydraulic circuit
to remove air.
1)
Install water flow restrictor.
1)
Check water pressure does not exceed
150psi.(section
3.2
).
CE Flue blockage detected during operation due to
excessive pressure on the siphon.
Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Check air openings and exhaust opening for
obstructions and reset the error.
Check if the air filter is dirty or clogged.
Perform gas and air tuning ( section 8.11).
1)
Contact Bosch support line for additional
information and assistance in case of installation in
dusty areas.
CF Flue blockage detected during operation due to
insufficient combustion air.
Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Check air openings and exhaust opening for
obstructions and reset the error.
Check if the air filter is dirty or clogged replace it if
needed.
Perform gas and air tuning ( section 8.11).
1)
If the problem persists:
Contact Bosch support line for additional
information and assistance in case of installation in
dusty areas.
E0 Electronic control unit internal error. Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
E1 Hot water temperature above 194 °F (90 °C).
Appliance burner cut off to prevent scalding and
reactivation after cooling down.
Disconnect the appliance and purge hydraulic circuit
to remove air.
If the problem persists:
Reduce setpoint temperature to minimize
temperature instabilities.
E3 Flue gases temperature above 167 °F (75 °C) or 2
minutes above 145 °F (63 °C).
Appliance burner cut off to prevent overheating.
Descale appliance ( section 7.3).
1)
Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
Check sensor resistance [15] (section 11) and
replace the sensor if it is not according to
specification.
1)2)
Display Description Solution