ELETTRODOMESTICI
VIA CHECCHI 98
I 21013 GALLARATE
ITALY
Page 5 of 28
Tuesday, June 18, 2002
BOSCH 700 SERIES:
SERVICE INSTRUCTIONS FOR OVEN TESTING AND BASIC TROUBLESHOOTING
WARNINGS
Ø DON’T PRESS [COOKING MODE] KEY BEFORE ENTERING MANUAL TEST. THE PROCEDURE WILL BE DISABLED.
Ø MANUAL TEST CAN BE ACCESSED WITHIN 5 MINUTES AFTER POWER-UP.
Ø MANUAL TEST QUITS AFTER A 4 MINUTES TIME-OUT IF IDLE.
The control is still configured as a double, at this point. Only on a single oven, missing the lower cavity, the following error messages
will be displayed:
Ignore it and enter the MANUAL TEST through the following procedure:
MANUAL TEST ACCESS PROCEDURE (both for DBL and SGL):
1. Press [CANCEL] key.
2. Turn the knob 4 detents CW.
3. Turn the knob 6 detents CCW.
4. Press [START] key.
The writing MANUAL TEST is displayed. Now press [Cooking Mode] key, the control will recognize automatically if the oven is a single
or a double. Turn the knob to select the correct oven model.
POWER UP SEE
CAL VAL ERROR
(CONDITION)
SLV_EE CHIP/
CKT BAD OR
RTDS NOT CAL
DO NOT USE
OVEN
CALL SERVICE