General Information
Overall Dimensions
Level
Tips
Preparation
Electrical Requirements
Table 1: Overall Dimensions
Dimension Inches centimeters
Height 36 91.44 cm
Width 29 5/16" 74.55 cm
Depth 25 5/8" 65.09 cm
For best results, cabinets, countertops walls and floors in the installation location
should be as level and plumb as possible. Variance may cause damage to coun-
tertops and floors during installation, could jeopardize the seal around the cooktop
and may adversely affect cooking and baking performance.
Tape warming drawer shut to keep it from opening while installing the range.
During installation, place a portion of the box or a piece of cloth under the range to
protect floors.
To make range lighter and easier to handle remove door (see instructions in Use
and Care manual).
Refer to data plate for more information. See "Product Data Plate" on page 17 for
data plate location.
We recommend that the range be installed with a power cord set (not supplied). 1
The electrical rating of the power cord set must be 120/240 volt, 40 or 50 amperes
minimum (depending on local code). The power cord set shall be marked "For
Use with Ranges." Always use a new power cord.
Note: In Canada, the range is shipped from the factory with the range cord
already installed.
Ranges are dual rated for use on either 120/240 VAC or 120/208 VAC. Check the
data plate for the kW rating. Reference the kW rating in the table below to deter-
mine amperage requirements.
Table 2: Electrical Specifications
kW Rating Hz Amps Req'd
120/240V 120/208V
13 9.8 60 40 or 50a
13.8 10.4 60 40 or 50a
[ ..........................................................................................................................
a. Varies by location. Check local codes.
1.Not needed for Canadian installations
English 3