EasyManua.ls Logo

Bosch HydroPower 10H - User Manual

Bosch HydroPower 10H
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Installation & Owners Guide
HydroPower
External Models
10H, 13H & 16H
Service Department: 1300 30 70 42
www.bosch.com.au
To be installed and serviced only
by an authorised person
This appliance is not suitable for
use as a pool heater
The “authorised installing person”
is responsible for:
1. Correct commissioning of this
appliance.
2. Ensure unit performs to the
specifications stated on the rating
label.
3. Demonstrate operation of unit to
customer before leaving.
4. Hand these instructions to
customer
.
This appliance must be installed in accordance with the manufacturer’s
installation instructions, AS 5601 (AG 601), NZ 5261, AS3500.4.2 and all
Local Water,Building and Gas fitting regulations
.
Failure to install this appliance in accordance with these installation
instructions may void warranty
In the interest of continued product improvement, Bosch reserves the
right to alter these specifications without notice

Questions and Answers

  • G
    gmillerJul 26, 2025
    How to fix a Bosch Water Heater that does not light?
    • M
      Mckenzie AustinJul 27, 2025
      If your Bosch Water Heater isn't lighting, here are a few things to check: First, make sure the switch is turned on. If it is on, the hydrogenerator might be jammed, in which case you should clean it. Also, ensure that the water flow is greater than 3.2 liters per minute.
  • J
    Joshua TurnerAug 3, 2025
    Why is there low water temperature in my Bosch HydroPower 10H?
    • S
      Sarah ColonAug 3, 2025
      Several factors can cause low water temperature in your Bosch Water Heater. The water flow selector might be in the warm position – set the flow rate to your individual needs. There could also be low gas pressure – check the gas pressure. Finally, check for a cross connection and if present disconnect the hot outlet with cold off and correct the connection.
  • K
    Keith FieldsAug 10, 2025
    Why is the burner flame low and the water not heating up in my Bosch HydroPower 10H Water Heater?
    • B
      bennettrebeccaAug 10, 2025
      If you're experiencing a low burner flame and the water isn't heating up in your Bosch Water Heater, several factors could be responsible. Check the supply regulator and pipe size, as low inlet gas pressure can cause this. Also, inspect the appliance regulator for low burner pressure. Low water flow can also affect the burner flame, so check the water flow rate. Finally, ensure the slide control is moved to high, since a low flame can be the reason.
  • C
    Charles HawkinsAug 18, 2025
    What to do if there is low water flow from my Bosch HydroPower 10H?
    • J
      Jeanette MartinAug 18, 2025
      If you're experiencing low water flow from your Bosch Water Heater, it could be due to several reasons. Check and adjust the water pressure, as low water pressure can cause this issue. A blocked water valve can also restrict flow, so clean the filter. Additionally, inspect the shower rose or tap aerator for blockages and clean them if necessary.

Summary

Bosch HydroPower Product Overview

External HydroPower Models

Details of external models for constant hot water supply.

Internal HydroPower Models

Details of internal models for space-saving, endless hot water.

Bosch HydroPower Specifications

Product Diagram and Dimensions

Visual layout and physical measurements of the appliance.

Product Characteristics

Key technical specifications and performance data.

Operating the Bosch HydroPower

Starting and Shutting Off Appliance

Step-by-step guide to powering the unit on and off.

Controlling Heat Output

Instructions on adjusting the appliance's heat output level.

HydroPower Operational Guidance

Water Flow and Temperature Adjustment

How to adjust water flow and its impact on water temperature.

Safety Warnings and Freezing Precautions

Critical safety alerts and advice on preventing freezing damage.

Troubleshooting and Maintenance

Common Issues and Solutions

Addresses common symptoms and provides troubleshooting steps.

Care and Servicing Recommendations

Guidelines for periodic inspection and cleaning by professionals.

Bosch HydroPower Installation Steps

Water Pressure and Connection Specs

Requirements for water supply pressure and connection types.

Natural Gas Inlet Pressure Testing

Procedure for testing and setting Natural Gas inlet pressure.

Bosch HydroPower Gas Setup

LPG Gas and Burner Pressure Adjustment

Guidance on LPG installation and burner pressure settings.

Minimum Gas Pressure Adjustment

How to correctly adjust the minimum gas pressure.

Regulatory Compliance and Clearances

Appliance Location and Safety Clearances

Rules for appliance placement and required safety clearances.

Bosch HydroPower Warranty

Warranty Terms and Conditions

Details warranty periods, claims, and purchaser's rights.

Terms of Delivery and Sale Exclusions

Specific exclusions and conditions affecting product warranty.

Bosch Environmental Commitment

Sustainability in Design and Production

Bosch's focus on environmental sustainability in appliances.

Bosch HydroPower 10H Specifications

General IconGeneral
Power17.4 kW
Maximum water temperature60°C
Flow rate at ΔT 25 K10 l/min
TypeTankless Water Heater
IgnitionHydropower
Gas TypeNatural Gas or LPG
Flow Rate10 L/min
VoltageNot Applicable
CurrentNot Applicable
Flow rate at ΔT 35 K7 L/min