1
Installation & Owners Guide
HydroPower
External Models
10H, 13H & 16H
Service Department: 1300 30 70 42
www.bosch.com.au
To be installed and serviced only
by an authorised person
This appliance is not suitable for
use as a pool heater
The “authorised installing person”
is responsible for:
1. Correct commissioning of this
appliance.
2. Ensure unit performs to the
specifications stated on the rating
label.
3. Demonstrate operation of unit to
customer before leaving.
4. Hand these instructions to
customer
.
This appliance must be installed in accordance with the manufacturer’s
installation instructions, AS 5601 (AG 601), NZ 5261, AS3500.4.2 and all
Local Water,Building and Gas fitting regulations
.
Failure to install this appliance in accordance with these installation
instructions may void warranty
In the interest of continued product improvement, Bosch reserves the
right to alter these specifications without notice

Questions and Answers

  • J
    James GriffithAug 8, 2025
    How to fix a Bosch Water Heater that does not light?
    • M
      Michelle PooleAug 8, 2025
      If your Bosch Water Heater isn't lighting, here are a few things to check: First, make sure the switch is turned on. If it is on, the hydrogenerator might be jammed, in which case you should clean it. Also, ensure that the water flow is greater than 3.2 liters per minute.
  • J
    Jason JohnsonAug 15, 2025
    Why is there low water temperature in my Bosch Water Heater?
    • M
      Monique EdwardsAug 15, 2025
      Several factors can cause low water temperature in your Bosch Water Heater. The water flow selector might be in the warm position – set the flow rate to your individual needs. There could also be low gas pressure – check the gas pressure. Finally, check for a cross connection and if present disconnect the hot outlet with cold off and correct the connection.
  • D
    Douglas FosterAug 23, 2025
    Why is the burner flame low and the water not heating up in my Bosch Water Heater?
    • N
      nmartinAug 23, 2025
      If you're experiencing a low burner flame and the water isn't heating up in your Bosch Water Heater, several factors could be responsible. Check the supply regulator and pipe size, as low inlet gas pressure can cause this. Also, inspect the appliance regulator for low burner pressure. Low water flow can also affect the burner flame, so check the water flow rate. Finally, ensure the slide control is moved to high, since a low flame can be the reason.
  • C
    Crystal FrazierAug 30, 2025
    What to do if there is low water flow from my Bosch Water Heater?
    • D
      Drew MoralesAug 31, 2025
      If you're experiencing low water flow from your Bosch Water Heater, it could be due to several reasons. Check and adjust the water pressure, as low water pressure can cause this issue. A blocked water valve can also restrict flow, so clean the filter. Additionally, inspect the shower rose or tap aerator for blockages and clean them if necessary.

Summary

Introduction and Background

Product Overview

Explanation of how HydroPower ignition works and its benefits.

External HydroPower

Models for constant, reliable hot water service, endless hot water without a power point.

Internal HydroPower

Units for limited space, providing endless hot water, operable without a power point.

Product Diagram

Dimensions

Table detailing the physical dimensions of the 10H, 13H, and 16H models.

Product Characteristics

Table listing key technical specifications for each model.

Operating Instructions

Starting and Shutting Off the Appliance

Steps for turning the unit on and off, and indicator light meanings.

Output Control

How to adjust the appliance's heating output using the control.

Water Flow Adjustment

Warning

Freezing Weather

CAUTION

Trouble Shooting

Appliance does not light

Troubleshooting steps for when the appliance fails to ignite.

Smell of gas

Procedure for addressing a gas smell, emphasizing safety and leak detection.

Low burner flame, water does not heat up.

Solutions for low heating performance, checking gas and water flow.

Low water temperature

Causes and fixes for insufficient hot water temperature.

Low water flow

How to diagnose and resolve issues with low water flow.

Care & Servicing of the Unit

10 Basic Steps for Installation

Check cold water supply pressures

Ensuring minimum and maximum water supply pressures meet specifications.

Connection sizing

Recommended pipe connection sizes for hot/cold water and gas types.

Determine most suitable location

Guidelines for selecting the optimal installation location for the appliance.

Secure Heater to wall

Instructions for securely mounting the appliance to the wall.

Locate & connect cold and hot water piping

Connecting water pipes, including advice on valves and pressure limits.

Test Inlet Gas Pressure

Procedure for testing and adjusting inlet gas pressure for Natural Gas.

Minimum Gas Pressure Adjustment

Regs Chart

APPLIANCE LOCATION

Requirements for appliance installation location, emphasizing outdoor use only.

CLEARANCES FOR FLUE TERMINAL

Mandatory clearances around the flue terminal for safe installation.

Overview of Warranty Conditions

What to do before contacting Bosch for Servicing assistance.

Checks to perform before requesting service assistance for the appliance.

Authorised Service Dealers

Contact information for locating the nearest authorised service dealer.

Warranty

Details of the warranty period and coverage for domestic and commercial use.

Purchasers Statutory Rights

Information on consumer rights and how the Bosch warranty supplements them.

Extract of Terms of Delivery and Sale

Terms and conditions related to product warranty, repair, and exclusions.

Bosch & the Environment

Bosch HydroPower16H Specifications

General IconGeneral
BrandBosch
ModelHydroPower16H
CategoryWater Heater
LanguageEnglish

Related product manuals