Trouble Shooting
Symptom Possible Cause Solution
Appliance does not light Switch turned off
Hydrogenerator Jammed
Low Water Flow
Turn switch on
Clean hydrogenerator
Increase water flow >3.2
litres per minute
Smell of gas Gas Leak Locate leak with soap
solution
Low burner flame, water
does not heat up.
Low inlet gas pressure
Low burner pressure
Low water flow
Low flame
Check supply regulator &
pipe size.
Check appliance regulator
Check water flow rate
Move slide control to high
Low water temperature Water flow selector in
warm position
Low Gas pressure
Cross connection
Set flow rate to individual
need.
Check gas pressure
Disconnect hot outlet with
cold off. Correct
connection
Low water flow Low water pressure
Blocked water valve
Blocked shower rose or
tap aerator
Check and adjust
Clean filter
Clean
Care & Servicing of the Unit
We recommend that the appliance be inspected and cleaned by an authorised
person periodically, depending on the frequency and duration of its operation, but
never less than once in a two year period.