Callout - Description
1 – Control panel
2 – Terminal wiring
3 – Codepad’s wiring terminal block
Icon Codepad Indicators
Codepad indicator
icons
Status Definition
ZONE 1 – 8 for ICP-
SOL2-P
ZONE 1 – 16 for ICP-
SOL3-P
On Zone is unsealed.
Off Zone is sealed.
Flashing Fast (0.25 sec
on/0.25 sec off)
Zone is in alarm condition.
Flashing Slow (1 sec on/1
sec off)
Zone is manually isolated or selected to
be isolated.
AWAY
On System is armed in AWAY Mode.
Off System is not armed in AWAY Mode.
Flashing twice a sec with
STAY indicator
Setting STAY Mode 2 zones.
STAY
On System is armed in STAY Mode 1 or
STAY Mode 2.
Off System is not armed in STAY Mode 1 or
STAY Mode 2.
Flashing twice a sec Zone isolating mode
Flashing twice a sec with
AWAY indicator
Setting STAY Mode 2 zones.
Flashing once every 3 sec Day alarm status – day alarm turned on.
On System is disarmed.
MAINS
On AC MAINS power normal.
Flashing AC MAINS supply has failed.
FAULTS
On There is a system fault that needs to be
rectified.
Off The system is normal, there are no
faults.
Flashing There is a system fault that needs to be
acknowledged.
4.1.1
18 en | Accessories Control Panel
2014.07 | 00n | F01U298026 Installation Guide