823_58300000113594_ara_en_u – 26.03.2015 Seite 12 von 50
5 FUNCTIONS
5.1 Test programme
Entering the programme:
► Press the Lock button.
► Press and hold down the freezer set button.
► Press the Super Freeze button 5 times.
Press the Freezer Set button to select the individual test steps and the
fault displays.
Run time of the appliance (in hours and minutes) After 24
h the display starts at 1 min
Freezer compartment sensor temperature
(e.g. –F1 65 = –16.5 °C)
Defrosting sensor temperature (e.g. –d1 82 = –18.2 °C)
Refrigerator compartment sensor temperature
(e.g. – r0 55 = 5.5 °C)
Room sensor temperature (e.g. t2 82 = 28.2 °C)
Change water supply quantity display P100
Press the Dispenser button to display the remaining time
(in hours and minutes) until the water filter is next
changed. FiLt display
If there is a fault, it is displayed here (see Fault display)
Exiting the programme:
► Press the Lock button for 4 sec.
If no button is pressed for 4 min., the appliance automatically switches
back to normal mode.