6.10 Changing the water supply flow rate
The water flow rate is controlled by a flow sensor. The flow sensor
is located in the water supply valve and cannot be changed.
The water supply flow rate can be adjusted as follows:
► Press the Lock button.
► Press and hold down the freezer Set button.
► Press the Super Freeze Set button 5 times.
► Press the Freezer Set button 5 times until P100 is displayed.
Factory setting : P100 = 86 ml
► Pressing the Super Cool button increases the water flow rate
P101 = 87 ml, P102 = 88 ml, etc.
► Pressing the refrigerator Set button reduces the water flow
rate
P99 = 85 ml, P98 = 84 ml, etc.
Exit programme:
► Press the Lock button for 4 sec.
If no button is pressed for 4 min., the appliance automatically returns
to normal mode.