823_58300000113594_ara_en_u – 26.03.2015 Seite 37 von 50
6.18.4 Carrying out the sanitisation
Exposed live parts
Risk of death due to electric shock
► Disconnect the appliance from the mains.
► Use the current-operated circuit breaker if live tests are
required.
► Do not touch the housing, frame, or components.
► Ensure that the resistance of the earthing conductor does not
exceed the standardised value.
Injuries may be caused by liquid spraying out
► After finishing the sanitation work, empty the pressure tank
completely and depressurise it.
Any microbiological substance in the water filter is not
sufficiently removed by sanitisation
► Before sanitisation, replace the filter with a bypass.
► After sanitisation, replace with a new filter.
The microbiological substance is not sufficiently reduced in
the water system
To successfully sanitise the appliance, all quantity and time
specifications must be complied with.