EasyManua.ls Logo

Bosch PLR 50 C - Product Description and Specifications; Intended Use; Technical Data

Bosch PLR 50 C
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English | 27
Bosch Power Tools 1 609 92A 1F3 | (20.8.15)
in direct vicinity being harmed cannot be completely exempt. Do not use the
measuring tool with Bluetooth® in the vicinity of medical devices, petrol sta-
tions, chemical plants, areas where there is danger of explosion, and areas
subject to blasting. Do not use the measuring tool with Bluetooth® in air-
planes. Avoid operation in direct vicinity of the body over longer periods.
Do not use the measuring tool if the touchscreen is visibly damaged (e.g.
cracks in the surface etc.).
The Bluetooth® word mark and logos are registered trademarks owned by Blue-
tooth SIG, Inc. and any use of such marks by Robert Bosch GmbH is under li-
cense.
Product Description and Specifications
Intended Use
The measuring tool is intended for measuring distances, lengths, heights, clearances
and inclines, and for calculating areas and volumes.
The measuring results can be transferred to other devices via Bluetooth®.
The help function integrated into the measuring tool provides detailed animations
about individual measuring functions/procedures.
Technical Data
Digital Laser Measure PLR 50 C
Article number
3 603 F72 2..
Distance measurement
Measuring range 0.0550 m
A)
Measuring accuracy (typical) ±2.0mm
B)
Lowest indication unit 0.1 mm
Inclination measurement
Measuring range 0°–36 (4x9)
Measuring accuracy (typical)
±0.
C)/E)
Lowest indication unit 0.1°
General
Operating temperature –10 °C...+50 °C
D)
Storage temperature –20 °C...+70 °C
Relative air humidity, max.
90 %