© Bosch Connected Devices and Solutions GmbH 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing,
distribution, as well as in the event of application for industrial property rights.
3 Technical specifications
Table 1 Device specifications - Parking Lot Sensor PLS with TPS110 sensor core
Additional information can be found in the datasheet on the website at https://www.bosch-connectivity.com/parking-lot-
sensor/downloads/.
Risk of interference to other radio services and malfunction.
Operation of the TPS110 variant out of the Target Markets specified in Chapter 4 can cause disturbance
of other services and can be subject of legal prosecution. Regulatory notices for other countries are
included in Chapter 4 of the English part of this user manual.
⇒ Ensure that TPS110 variants are operated only in the target markets with a valid approval statement.
⇒ Ensure that it is connected to LoRa gateways that are certified for operation in the target markets and
support the regional channel plans published by the LoRa Alliance.
LoRa frequencies and LoRa Channel Plans
(RP002-1.0.0)
TPS110 EU: 863-865/868-868.6/869.4-869.65 MHz (EU868)
Transmitting power max. 14 dBm ERP
Supported channel frequencies: 864.1 MHz, 864.3 MHz, 864.5 MHz,
868.1 MHz, 868.3 MHz, 868.5 MHz, 869.525 MHz
Note: For TPS110 EU core used in Rep. of South Africa the
K-Band 863-865MHz is deactivated.
TPS110 IN: 865-867 MHz (IN865)
Transmitting power max. 14 dBm ERP
TPS110 JP: 920-923.4 MHz (AS923)
Transmitting power max. 14 dBm ERP
TPS110 US: 902-928 MHz (US902-928)
Transmitting power max. 14 dBm ERP
2.4-2.4835 GHz
Transmission power max. -28 dBm EIRP